1.1 Cross-corder Detection
Picture-1
【 Motion area Setting】 Set Cross-border area. Click the “Motion area Setting”, and then click in the screen to pull the mouse, will appear a cross-border line length, enough to click cross-border again after the drawing is completed. Second, draw the direction, click on the left or right side of the border there will be a line with an arrow, the direction of the arrow, is the direction of cross-border detection, Picture-2.
Picture-2
【Clear 】 Clear all the cross-border line。
【Cross-border Detection】On/Off Cross-border Detection, Default Off.
【Time】Set alarm detection arming time period. You can set the specific time of day.
【Linkage Alarm output】Alarm triggers the built-in relay switch alarm output
【Alarm output duration】Set the alarm linkage alarm output duration, in seconds, the time value is limited to 0 ~ 86400 seconds. When the time value is 0, the alarm output is unlimited
【Email】The motion detection alarm information to inform users by E-mail【Email parameter】。
【Snapshot】After the alarm is triggered, the linkage device captures and stores on the device-side hard disk. Snapshot parameters, if you set the number of snapshots to 5, the capture interval of 1 second, refers to the alarm capture a 5 pictures, each picture interval of 1 second. And can be set to send e-mail or FTP upload saved snapshot images.
【Record】After the alarm is triggered, the video of the linkage device is recorded and stored on the device-side hard disk. And set up FTP upload to save the video file.
【 Audio Out】After turning on, when the device is connected to the output device and a motion alarm occurs, the audio output device will have a sound output.
After setting all the parameter,click【Save】Settings to take effect。
When detecting the alarm, you can browse the page in real time,open【Area】You can check the detection area and alarm status, if there is alarm, the border will flash。
Note: The video packaging time is equal to the duration of the alarm trigger plus the time set in the linkage video parameter.
1.2 Regional Invasion
Picture-3
Check the detection area in the screen for intrusion.
【Motion area setting】 Set the detection area. Click on the regional settings in the preview window by left-clicking the four points, draw a region set to the invasion of the region, when there is movement of the body after the invasion area will alarm, picture-4。
Picture-4
【All】Set the entire video area as intrusion detection area
【Clear】Clear the set area
【Regional Invasion Detection】On/Off Regional Invasion Detection, Default Off.。
【Time】Set alarm detection arming time period. You can set the specific time of day.
【Linkage Alarm Output】Alarm triggers the built-in relay switch alarm output。
【Alarm output duration】Set the alarm linkage alarm output duration, in seconds, the time value is limited to 0 ~ 86400 seconds. When the time value is 0, the alarm output is unlimited
【E-mail】The motion detection alarm information to inform users by E-mail【Email parameter】。
【Snapshot】After the alarm is triggered, the linkage device captures and stores on the device-side hard disk. Snapshot parameters, if you set the number of snapshots to 5, the capture interval of 1 second, refers to the alarm capture a 5 pictures, each picture interval of 1 second. And can be set to send e-mail or FTP upload saved snapshot images.
【Record】After the alarm is triggered, the video of the linkage device is recorded and stored on the device-side hard disk. And set up FTP upload to save the video file.
【 Audio Out】After turning on, when the device is connected to the output device and a motion alarm occurs, the audio output device will have a sound output.
After setting all the parameter,click【Save】Settings to take effect。
When detecting the alarm, you can browse the page in real time,open【Area】You can check the detection area and alarm status, if there is alarm, the border will flash。
Note:
The video packing time is equal to the duration of the alarm trigger plus the
time set in the linkage video parameter
1.3 Unfocused Detection
Picture-5
Start the defocus detection, the device detects the lens out of focus, the device will automatically handle the corresponding event。
【Focus Switch】ON/OFF intelligent defocus detection
【OSD output】 When detecting the lens out of focus, the linkage screen output prompt, this feature needs to enable the screen output switch. Screen tips will disappear after the lens is clear.
【Linkage motion】Motion detection alarm needs to be enabled. When the camera is off and the motion alarm is enabled, the out of focus alarm will take effect.
1.4 Video Shade
Picture-6
Objects block the camera, the system determines the current area video anomalies
【Motion area setting】Press the left mouse button and drag to delineate the test area, up to four test areas can be set。
【All】Set the entire video as video anomaly detection area
【Clear】Clear all test areas
【Video Abnormal】Turn on / off video alarm detection, the default is off
【Sensitivity】Set the frequency of abnormal detection sensitivity, the range of 0 to 255, the higher the value the higher the sensitivity
【Time】Set alarm detection arming time period. You can set the specific time of day.
【Linkage Alarm Output】Alarm triggers the built-in relay switch alarm output。
【Alarm output duration】Set the alarm linkage alarm output duration, in seconds, the time value is limited to 0 ~ 86400 seconds. When the time value is 0, the alarm output is unlimited
【E-mail】The motion detection alarm information to inform users by E-mail【Email parameter】。
【Snapshot】After the alarm is triggered, the linkage device captures and stores on the device-side hard disk. Snapshot parameters, if you set the number of snapshots to 5, the capture interval of 1 second, refers to the alarm capture a 5 pictures, each picture interval of 1 second. And can be set to send e-mail or FTP upload saved snapshot images.
【Record】After the alarm is triggered, the video of the linkage device is recorded and stored on the device-side hard disk. And set up FTP upload to save the video file.
【 Audio Out】After turning on, when the device is connected to the output device and a motion alarm occurs, the audio output device will have a sound output.
After setting all the parameter,click【Save】Settings to take effect。
When detecting the alarm, you can browse the page in real time,open【Area】You can check the detection area and alarm status, if there is alarm, the border will flash。
Note: The video packing time is equal to the duration of the alarm trigger plus the time set in the linkage video parameter
Picture-7
By setting the ROI, the device will automatically control the video stream according to the current real-time video situation, which solves the problem of high-definition network cameras, large occupied bandwidth, low efficiency and large storage space. Reduce the hard disk capacity through intelligent code stream Storage exhausted, extend recording time, reduce the bandwidth requirements.Interface picture-58。
【Close】The switch of the smart code stream is off by default, as shown in FIG. 7. After selecting the smart code stream detection or setting area, the switch is opened and the open status is shown in Picture-8:
Picture-8
【Auto】The selected area of interest for bit stream intelligent control, the area will be set to maintain high-definition, not set area, the device will automatically reduce the bit stream
Picture-9
Sensitivity detection sensitivity is divided into low, medium and high three levels, the default is high。
【ROI】Set the need to use the smart code stream area, the largest support for four regions of interest。 Picture-10
Picture 10
Picture-11
When the video screen appears a certain monochrome, the system for data analysis, if the analysis of the data value is greater than the set value of the sensitivity, the system determines the current video color anomalies.
【Switch】Turns on / off color error detection. Close by default
【Sensitivity】Detection of color sensitivity of the unusual. Range 1-2000, default: 800, the user can set the value according to specific needs, the lower the value the more sensitive.
【Time】Set alarm detection arming time period. You can set the specific time of day.
【Linkage Alarm Output】Alarm triggers the built-in relay switch alarm output。
【Alarm output duration】Set the alarm linkage alarm output duration, in seconds, the time value is limited to 0 ~ 86400 seconds. When the time value is 0, the alarm output is unlimited
Contact: Hank Li
Phone: +8615814084834
Tel: +86-0755-33173331
Email: info@smiletech.com.cn